COVER

OPERATOR'S MANUAL

1050M‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​‌​​​‌​⁠​​​​‍⁠‍‌‌‌⁠⁠‌‍​⁠​‌‌‍​‌‌‌​‍

©2026 Kaivac, Inc. All rights reserved

Line drawing of the Kaivac 1050M cleaning machine with a wide squeegee on a handle at the top, a white bottle on the left, vacuum tanks, a trolley bucket, a battery housing and wrapped hoses
WARNING DO NOT ATTEMPT TO OPERATE THE UNIT BEFORE READING AND UNDERSTANDING THIS MANUAL. PAY CLOSE ATTENTION TO ALL WARNINGS, CAUTIONS AND NOTICES. FAILURE TO DO SO MAY CAUSE SERIOUS PERSONAL INJURY OR DEATH, AND/OR DAMAGE TO PROPERTY OR YOUR KAIVAC PRODUCT.
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE WITHOUT NOTICE. FOR MOST UP TO DATE SAFETY INFORMATION, VISIT KAIVAC.COM
SAVE THIS MANUAL FOR FUTURE REFERENCE VISIT KAIVAC.COM FOR FULL SPECIFICATIONS & TROUBLESHOOTING
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 1, used with permission. SES ref PF-6SV3-HTBR‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​‌​​​‌​⁠​​​​‍⁠‍‌‌‌⁠⁠‌‍​⁠​‌‌‍​‌‌‌​‍
1050M LMOF03_ONLINE (2026)Page 1 of 30
KAIVAC LIMITED WARRANTY

Kaivac Limited Warranty

In short This warranty covers the original purchaser against defects in material or workmanship when the Product is set up, operated, maintained, and stored as Kaivac recommends. Coverage periods differ by component, and accessories, misuse, unapproved modifications, and normal wear and tear are excluded.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​‍​​​‌​⁠​​​‌‍⁠‌‍⁠​‌⁠​‍⁠​⁠​‍​​‍​‌​‌

Kaivac, Inc. provides this Limited Warranty for the applicable Products and periods stated below, subject to certain limitations, to the original purchaser against defects in material or workmanship when the Product is properly set up, operated, maintained, and stored in accordance with Kaivac's recommendations. Unless otherwise extended by written agreement, for any covered defects in materials or workmanship, Kaivac will repair or replace the Product at its sole option, during the following coverage period(s) for each Product, its respective material(s) and/or component(s) as follows:‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​‍​​​‌​⁠​​​‌‍⁠‌‍⁠​‌⁠​‍⁠​⁠​‍​​‍​‌​‌

Limited Warranty Coverage and Periods of Warranty:

Kaivac extends the Limited Warranty on designated components of the Product for the coverage periods as specified below.

  1. TANK AND TROLLEY LIMITED WARRANTY. The vacuum tank and trolley (“Tank & Trolley”) are warranted to be free from defects in workmanship and materials for a period of Five (5) Years from the date the user purchases the Product.
  2. VACUUM MOTOR and PUMP LIMITED WARRANTY (excluding Battery). The Battery interface and components (excluding Lithium-ion battery), vacuum motor, and pump (collectively “Components”) are warranted to be free from defects in workmanship and materials for a period of Three (3) Years from the date the user purchases the Product. A Limited Lifetime Warranty for the OMNIFLEX vacuum motor is available to customers who purchase a Kaivac chemical subscription concurrently with the initial purchase of the OMNIFLEX unit and maintain the subscription without interruption for the duration of ownership. Eligibility for the warranty is conditioned upon the exclusive use of Kaivac-supplied chemicals in the OMNIFLEX unit. Any cancellation, lapse, or discontinuation of the subscription will immediately terminate the Limited Lifetime Warranty.
  3. LABOR LIMITED WARRANTY. Kaivac further warrants to the original purchaser any labor authorized by Kaivac and performed by a service provider, chosen or approved by Kaivac against defects in material or workmanship for One (1) Year from the date the labor was performed, not to exceed the original warranty on the part.
  4. BATTERY LIMITED WARRANTY. The lithium-ion battery (“Battery”) is warranted to be free from defects in workmanship and materials for a period of Two (2) Years from the date the user purchases the Product.
  5. REPLACEMENT PARTS. Replacement parts (“Parts”), which excludes Accessories, are warranted to be free of defects in workmanship and materials for a period of ninety (90) days from the date the user purchases the Part.

Limits of Warranty and Exclusions:

Kaivac's liability under this Limited Warranty is limited to the repair or replacement of a defective Product, at its sole discretion. This Limited Warranty DOES NOT include any warranty coverage for accessories to the Product(s) including, but not limited to accessory squeegee blades and wheels, hoses, seals, gaskets, cords, casters, HEPA filter cartridges, chemical feed caps, spray gun, GFCI, and vacuum wand assembly (individually, an “Accessory” and collectively, “Accessories”).

This Limited Warranty shall not apply to any Products that have been repaired, altered, or modified in a way, so as in Kaivac's sole judgment, adversely affects the operation, performance, or durability, or changes the Product's intended use. The Limited Warranty shall not apply to any Products which, in Kaivac's sole judgment, have been subject to misuse, abuse, negligence or accident, nor to any Products that have not been operated and maintained in accordance with Kaivac's instructions and recommendations. Compliance with the Limited Lifetime Warranty for OMNIFLEX vacuum motor shall be determined solely by Kaivac. In addition, the Limited Warranty does not cover damage caused by the following, as determined solely by Kaivac:

  • Any use inconsistent with the instructions and warnings for the Product;
  • Use of high-foaming or corrosive chemicals;
  • Use of a non-Kaivac battery or charger or improper installation of the Battery;
  • Loss of IoT functionality resulting from failure to maintain network connectivity for the Product or to allow Kaivac-issued firmware, security certificate, or software updates to be applied;
  • Use of Battery for more than Five (5) years after purchase;
  • Any accident, neglect or failure to operate and maintain the Product according to Kaivac's instructions and warnings; and
  • Any modification or attempt to modify the Product by anyone other than Kaivac or a Kaivac approved service provider.
  • Normal wear and tear.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 2, used with permission. SES ref PF-WBCQ-57XX‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​‍​​​‌​⁠​​​‌‍⁠‌‍⁠​‌⁠​‍⁠​⁠​‍​​‍​‌​‌
1050M LMOF03_ONLINE (2026)Page 2 of 30
KAIVAC LIMITED WARRANTY

Kaivac Limited Warranty (Continued)

In short This page continues the Kaivac Limited Warranty. It covers who pays shipping and import costs for warranty claims, how repairs and replacements affect the warranty period, and the exclusions of liability. It also lists Kaivac contact details for warranty service.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​⁠​​​‌​⁠​​‌‍⁠‍‍⁠‍‍‍‍⁠‌‍‌‍‌​​‌⁠​⁠‌​

For warranty claims, the original purchaser shall be responsible for any freight, shipping, and travel costs associated with the repair or replacement provided for under this Limited Warranty. For warranty claims made outside the country of purchase, the original purchaser will be responsible for all import duty costs incurred.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​⁠​​​‌​⁠​​‌‍⁠‍‍⁠‍‍‍‍⁠‌‍‌‍‌​​‌⁠​⁠‌​

If Kaivac authorizes a repair, the repair warranty will not extend the time period of the of the original Product or Part's warranty period under this Limited Warranty.

If you obtain a replacement Product, this Limited Warranty applies to such replacement for the remainder of the original Product's warranty period.

Exclusions of Liability and Disclaimer of Implied Warranties: EXCEPT AS OTHERWISE EXPRESSLY STATED HEREIN, KAIVAC MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESSED OR IMPLIED. THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED FROM THIS LIMITED WARRANTY. TO THE EXTENT THEY CANNOT BE DISCLAIMED, THE IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE LIFE OF THE EXPRESS WARRANTY. THIS LIMITED WARRANTY ALSO EXCLUDES INDIRECT, INCIDENTAL, CONSEQUENTIAL, AND SPECIAL DAMAGES. THIS EXCLUSION OF INDIRECT, INCIDENTAL, CONSEQUENTIAL, AND SPECIAL DAMAGES IS INDEPENDENT FROM AND SHALL SURVIVE ANY FINDING THAT THE EXCLUSIVE REMEDY FAILED OF ITS ESSENTIAL PURPOSE. THE REMEDIES SET FORTH IN THIS WARRANTY ARE THE ONLY REMEDIES AVAILABLE TO ANY PERSON UNDER THIS WARRANTY. SOME STATES/PROVINCES DO NOT ALLOW FOR THE DISCLAIMERS, LIMITATIONS, AND EXCLUSIONS IDENTIFIED ABOVE AND, AS A RESULT, THEY MAY NOT APPLY TO YOU.

Upon purchasing any Product, purchaser assumes all liability, all personal injury and property damage resulting from the handling, possession or use of such Product. No agent, employee or representative of Kaivac, nor any independent retailer and/or dealer, is authorized to bind Kaivac to any affirmation, representation or warranty regarding the Products except as specifically contained in this Limited Warranty. Kaivac may modify this Limited Warranty.

Consult Kaivac.com for current Product(s) information and Limited Warranty. For any questions or warranty service, please contact Kaivac Customer Service at 1/800-287-1136 (Outside the U.S. Call 513-887-4600).

Version 7-9-2026

Phone:

United States and Canada: 1-800-287-1136

International: 1-513-887-4600

Email:

[email protected]

For Technical Support Contact Form go to: https://www.kaivac.com/contactus.php and choose Technical\Support tab.

2680 Van Hook Avenue, Hamilton, OH 45015 / 800-287-1136 / kaivac.com

Protected by multiple US patents. Multiple patents pending. © Copyright Kaivac, Inc. 2026

Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 3, used with permission. SES ref PF-RTTR-RDLD‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​​⁠​​​‌​⁠​​‌‍⁠‍‍⁠‍‍‍‍⁠‌‍‌‍‌​​‌⁠​⁠‌​
1050M LMOF03_ONLINE (2026)Page 3 of 30
IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

In short This section lists the basic safety precautions to follow when using the electrical unit, and explains the WARNING, CAUTION and NOTICE signal words. It covers general rules, spray system rules and rules for corded units, and says to read all instructions before using the unit.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌​​​​‌​⁠​​‍⁠⁠‌⁠‌​‍‌⁠‌‌‍‍‌⁠​​‍‌⁠‍‌​

SAVE THESE INSTRUCTIONS
CONSULT KAIVAC.COM FOR THE MOST UP TO DATE SAFETY PRECAUTIONS
READ ALL INSTRUCTIONS BEFORE USING (THIS UNIT)‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌​​​​‌​⁠​​‍⁠⁠‌⁠‌​‍‌⁠‌‌‍‍‌⁠​​‍‌⁠‍‌​

WARNING SAFETY ALERT WARNING indicates a hazardous situation which, if not avoided, COULD result in serious injury or death
CAUTION SAFETY ALERT CAUTION indicates a hazardous situation which, if not avoided, COULD result in minor to moderate injury.
NOTICE NOTICE provides key information by clarifying instructions.

When using an electrical unit, basic precautions should always be followed, including the following:

WARNING RISK OF ELECTRIC SHOCK, FIRE, EXPLOSION, AND SERIOUS PERSONAL INJURY OR DEATH

GENERAL SAFETY INSTRUCTIONS (APPLICABLE TO CORDED AND BATTERY UNITS):

  • For commercial use only.
  • Use unit only as described in this Manual. Use only Kaivac's recommended attachments.
  • Follow the maintenance instructions specified in this Manual.
  • For indoor use only. Store indoors.
  • Stay alert - watch what you are doing. DO NOT overreach or stand on unstable support. Keep good footing and balance at all times.
  • Keep operating area clear of all persons.
  • Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
  • NO COMBUSTIBLES! Sparks inside the motor can ignite flammable vapors or dust. Do not use unit near combustible liquids and gases, or to pick up explosive dusts or gasoline.
  • Know how to stop the unit and bleed pressures quickly. Be thoroughly familiar with the unit's controls before operating.
  • DO NOT allow unit to be used as a toy and unit should not be operated by children. Close attention is necessary when used near children.
  • Use extra care when cleaning on stairs.
  • DO NOT operate the unit when fatigued or under the influence of alcohol or drugs.
  • DO NOT put any object into unit's openings. Do not use with any of the unit's opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
  • DO NOT pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
  • DO NOT operate without the Vacuum Motor Float Cage installed. If float is removed, reinstall by screwing back into place.
  • DO NOT use without filters in place.
  • Personal Protective Equipment (PPE): It is recommended to wear proper personal protective equipment as required by the chemical product label instructions used in conjunction with the unit. For Kaivac chemical products, refer to product label.

SPRAY SYSTEM SAFETY INSTRUCTIONS:

  • DO NOT spray liquid from the unit or attachments onto electrical outlets or any electrical devices.
  • Risk of injection or injury to persons - DO NOT direct discharge stream at persons.
  • INJECTION HAZARD: Unit can cause serious injury if the spray permeates the skin. Do not point the spray gun at anyone or any part of the body. In case of permeation, seek medical aid immediately.
  • THIS UNIT IS CAPABLE OF PRODUCING 500 PSI (3447 kPa). To avoid rupture and injury, do not operate this pump with components rated less than 500 PSI (3447 kPa) working pressure (including but not limited to spray guns, hose, and hose connections); and before servicing, cleaning or removal of any part, shut off power and relieve pressure.
  • High pressure cleaners, such as this unit, shall not be used by children, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge or untrained personnel. Children should not play with the unit. Cleaning and user maintenance should not be performed by children.

CORDED UNITS SAFETY INSTRUCTIONS (APPLICABLE TO CORDED UNITS):

  • Inspect cord and plug prior to use. Do not use with damaged cord or plug. If unit is not working as it should, has been dropped, damaged, left outdoors or dropped into water, do not use or charge and return unit to a Kaivac service center.
  • This unit may also have been provided with a ground fault circuit interrupter (GFCI) built into the power cord. If replacement of the plug or cord is needed, use only identical replacement parts. Test the unit's ground fault circuit interrupter (GFCI) before each use.
  • Turn off the unit before unplugging. Do not leave unit when plugged in. Unplug from outlet when not in use and before servicing.
  • Turn off all controls before unplugging.
  • Connect to a properly grounded outlet only. Do not remove ground pin on plug. See Grounding Instructions below.
  • This unit comes with a grounded attachable extension cord. If cord is damaged, replace with equivalent 120v, 15amps, 14GA rated cord. This cord must be attached and mechanically secured using the provided cord connector to use the unit.
  • The unit must be disconnected from any electrical or battery source when the unit is being cleaned or maintenance of unit or when replacing parts
  • Keep all connections dry and off the ground. If using extension cord with unit, make sure the connection is above and off the floor and away from exposure to liquid.
  • Keep the cord away from heated surfaces.
  • DO NOT handle plug or unit with wet hands.
  • DO NOT pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners. Do not run unit over cord. Keep cord away from heated surfaces.
  • DO NOT unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 4, used with permission. SES ref PF-ZIL7-64QU‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌​​​​‌​⁠​​‍⁠⁠‌⁠‌​‍‌⁠‌‌‍‍‌⁠​​‍‌⁠‍‌​
1050M LMOF03_ONLINE (2026)Page 4 of 30
IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS (CONTINUED)

SAVE THESE INSTRUCTIONS
CONSULT KAIVAC.COM FOR THE MOST UP TO DATE SAFETY PRECAUTIONS
READ ALL INSTRUCTIONS BEFORE USING (THIS UNIT)‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌‌​​​‌​⁠​​⁠‌⁠‍‌​‍​⁠​‌‌​‌​‍‌⁠​​⁠‍​⁠

When using an electrical unit, basic precautions should always be followed, including the following:

Orange WARNING label with a lightning bolt in a yellow triangle and the text RISK OF ELECTRIC SHOCK, FIRE, EXPLOSION, AND SERIOUS PERSONAL INJURY OR DEATH

BATTERY UNITS SAFETY INSTRUCTIONS (APPLICABLE TO BATTERY UNITS):

In short This section lists safety rules for units that run on batteries. Use only the Kaivac battery and charger, never use or charge a damaged battery, and keep batteries away from fire, heat, water and metal objects.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌‌​​​‌​⁠​​⁠‌⁠‍‌​‍​⁠​‌‌​‌​‍‌⁠​​⁠‍​⁠

Batteries and chargers: make sure your charger is compatible with your batteries, and set its charging algorithm to your battery pack before you use it.

WARNING! RISK OF ELECTRIC SHOCK, FIRE, EXPLOSION, AND SERIOUS PERSONAL INJURY OR DEATH
  • Never use a battery that has been damaged in any way. Damaged batteries may exhibit unpredictable behavior.
  • Never use or charge a damaged battery pack.
  • ONLY USE with Kaivac, Inc. battery, and charger.
  • Inspect the battery before each use for damage, dents, cracks, or holes.
  • If included with legacy unit, the battery splash cover must remain in place. Without the battery splash cover, the battery housing may become damaged which may cause the battery to malfunction, which can result a fire, explosion, personal injury, and/or property damage.
  • If your unit contains a chemical-resistant plastic protective helmet, consult the Helmet Addendum for additional instructions and warnings.
  • Exposure of units to airborne polyunsaturated fats in the food service industry may cause deterioration of battery components. Failure to inspect and use as instructed may result in fire explosion, personal injury, or property damage.
  • Under certain conditions, including damage or liquid infiltrating the battery's interior cells, the battery may emit smoke, sparks, or fire. Liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
  • Stop use immediately if the battery or unit sparks or shows signs of fire. And may result in fire.
  • If unit or battery emits fumes, smoke, sparks, or fire, discontinue use immediately. Do not touch battery. If unit can be safely moved, move outside to a well ventilated fire safe area away from people or combustible material.
  • DO NOT attempt to repair, service or modify the batteries or charger. Contact Kaivac Technical Support with any issues.
  • Disconnect the battery from the unit before making any adjustments, changing accessories, or storing unit. Such preventive safety measures reduce the risk of starting the unit accidentally.
  • When charging battery, make sure charger or unit has at least 6 inches of clearance on all sides for adequate air flow.
  • When battery is not in use, keep it away from other metal objects like paper clips, coins, keys, nails, screws or other small metal objects that can make a connection from one terminal to another. Connecting or shorting the battery terminals together may cause burns or a fire.
  • Keep heat sources, sparks, and flames away from batteries.
  • Prevent unintentional starting. Ensure the switch is in the off-position before connecting to battery, picking up or carrying the unit. Do not carry the unit with your finger on the switch. Energizing an unit that has the switch on invites accidents.
  • DO NOT allow battery to be submerged in water.
  • DO NOT use a battery that has been submerged in water, or if water has infiltrated the battery housing even if it appears to be working.
  • DO NOT charge batteries outdoors.
  • DO NOT short-circuit the battery or charger terminals with conductive items such as paper clips. This can deliver high current.
  • DO NOT crush or drop the battery.
  • DO NOT expose a battery or unit to fire or excessive temperature. Exposure to fire or temperature above 265°F (130°C) may cause explosion.
  • DO NOT use or store the NTC System or battery in refrigerated areas, in environments when the battery is in direct contact with liquids, or near flammable or combustible materials.
  • DO NOT charge or store battery for extended time (1 month or more) in temperatures below 40°F (4°C).
  • DO NOT remove any part of the battery, charging unit, or unit: If your unit has a chemical-resistant plastic protective helmet, do not remove it.
  • DO NOT plug battery in while Vacuum Motor is in ON position. It may damage the system.
  • DO NOT incinerate the battery even if it is non-working or severely damaged. The battery can explode in a fire.
  • DO NOT leave battery connected to charger once the charger light is green. Leaving battery on charger will diminish the life of the battery
  • Never dispose of the battery in the trash. It is important that your old, damaged battery is disposed of and/or returned as instructed by Kaivac Customer Care/Technical Support at 1-800-287-1136.
Orange WARNING label with a lightning bolt in a yellow triangle and the text RISK OF ELECTRIC SHOCK, FIRE, EXPLOSION, AND SERIOUS PERSONAL INJURY OR DEATH

CHARGER/ELECTRICAL WARNINGS:

In short These warnings cover safe use of the charger and its cord. Inspect the charger before each use, plug it only into a properly grounded outlet, and never use it if it is damaged.

Batteries and chargers: make sure your charger is compatible with your batteries, and set its charging algorithm to your battery pack before you use it.

WARNING! RISK OF ELECTRIC SHOCK, FIRE, EXPLOSION, AND SERIOUS PERSONAL INJURY OR DEATH
  • Inspect the charger, cords, and connections prior to each use.
  • Follow all charging instructions and do not charge the battery or unit outside of the temperature range specified in the instructions. Charging improperly or at temperatures outside of the specified range may damage the battery and increase the risk of fire.
  • Connect charging cord to a properly grounded outlet only. See Grounding Instructions.
  • DO NOT use charger if it has a damaged cord or plug.
  • DO NOT operate charger if it has received a sharp blow, been dropped, or damaged in any way.
  • DO NOT handle charger, including charger plug and charger terminals, with wet hands while charger is plugged in or while inserting plug into electrical outlet.
  • DO NOT leave charger plugged in when not in use.
  • DO NOT plug in charger while Vacuum Head is in ON position. It may damage the unit's electrical system.
  • DO NOT pull on charger cord to unplug. Grasp and pull the plug, not the cord.
  • DO NOT carry charger by cord.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 5, used with permission. SES ref PF-F7GR-DPFA‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌‌​​​‌​⁠​​⁠‌⁠‍‌​‍​⁠​‌‌​‌​‍‌⁠​​⁠‍​⁠
1050M LMOF03_ONLINE (2026)Page 5 of 30
BATTERY INFORMATION

To recycle battery, call Kaivac Customer Care at 1-800-287-1136 to order a recycling box.
Disposal of batteries are regulated by federal law and must be done properly.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌‍​​​‌​⁠​​‌‌⁠​​​‌⁠​‍‌‌‌‍‍⁠⁠‌⁠‌‌​‍⁠

BATTERY INFORMATION

In short This section explains how to store, use and replace the lithium-ion battery. Keep it at room temperature, store it at about 50% charge, replace it when run time drops or after 4 years, and recycle old batteries rather than throwing them away.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌‍​​​‌​⁠​​‌‌⁠​​​‌⁠​‍‌‌‌‍‍⁠⁠‌⁠‌‌​‍⁠

Batteries and chargers: make sure your charger is compatible with your batteries, and set its charging algorithm to your battery pack before you use it.

Keep Batteries at Room Temperature: Store between 32 and 113 degrees F (0°C to 45°C). Avoid battery exposure to extreme temperatures. If shelving battery longer than (1) month, deplete battery to 50% charge during storage period (two bars on the battery indicator).

Batteries Lose Capacity Over Time: Batteries naturally deteriorate over time whether being used or not. If battery use instructions are properly followed, batteries deteriorate at a rate of approximately 10% run time per year but may vary by patterns of use.

Fully Discharge vs. Partial Discharge and the Effect on Battery Cycles: Unlike lead acid batteries, the Lithium-ion battery used with Kaivac equipment is not damaged by full or partial discharging. The expected battery hours of use are approximately 600 hours and 400 charge cycles. If you discharge battery only to 80%, then the user can expect to get more cycles (500 cycles). With dual batteries make sure to alternate batteries per charge in order to maximize for life capacity.

Extended Storage: It is recommended to discharge to 50% capacity (two bars on the battery indicator) and store in a cool location (between 32°F to 113°F or 0°C to 45°C). To avoid battery impact, store battery laying down on its side on lowest shelf, and secured. If battery is dropped or experiences an impact or damage, discontinue use and replace. Never use a damaged battery, as a damaged battery may act in an unpredictable manner resulting in fire, explosion, property damage, or personal injury.

Battery Gauge: The Kaivac provided battery comes with a built-in Battery Gauge or which shows the approximate run time for the current charge remaining.

Replacement - End of Life: Rechargeable batteries eventually wear out. When your Kaivac Battery run time is less than 55% (i.e. 50 minutes for non-quick change and 33 minutes for Quick Change batteries), Kaivac recommends replacing your battery. Regardless of run time, contact Kaivac to replace your battery after 4 years. Consult kaivac.com for information on recycling your old battery through a licensed disposal facility.

WARNING! RISK OF FIRE, EXPLOSION, PROPERTY DAMAGE, OR SERIOUS INJURY OR DEATH
DO NOT DISCARD BATTERY INTO TRASH! It is important to recycle your old batteries at your local authorized battery recycling facility or by calling 1-800-USA-CLEAN (1-800-872-2532) and selecting Option 3.
Battery Specifications
WeightWith Box, 11 lbs. (4,9 kg)
Body MaterialInjection Mold Polypropylene
Dimensions (H x W x D)18 x 7 x 5 in. (45,7 x 17,8 x 12,7 cm)
Voltage36V DC
Battery Capacity15 A-hr
Battery Current15 A DC
Battery TypeLithium-Ion
Approx. Run Time BOL (Beginning of Life)60 minutes
Approx. Run Time EOL (End of Life)35 minutes (discontinue use and take to recycling center)
Battery Box ReceptacleIP65 / IP67 (not required for UL)
Run Time Hour MeterActs as “odometer for battery” and runs only when motor switch is ON
Approx. Charge Cycles400 @ 100% discharge / 500 @ 80% discharge
Cut off Voltage (fully discharged)30V
Charger Specifications
Approx. Charge Time5 hours
Charger Amps4 Amps
Charge Voltage42V DC
Charger Voltage110-240VAC / 36VDC (240VAC version only needs correct plug for wall outlet)
Charging RobustnessNo special instructions
Battery Charge MemoryNone
Battery Charge GaugeYes, LED Indicator
Approx. Charge Cycles400 @ 100% discharge / 500 @ 80% discharge
Storage/Inventory:
Storage & Operation Ambient Temp32°F (0°C) to 113°F(45°C)
Storage & Shipping Charge40-60% Charge (35-38VDC)
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 6, used with permission. SES ref PF-IA65-NQAS‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌‍​​​‌​⁠​​‌‌⁠​​​‌⁠​‍‌‌‌‍‍⁠⁠‌⁠‌‌​‍⁠
1050M LMOF03_ONLINE (2026)Page 6 of 30
GROUNDING INFORMATION

GROUNDING INFORMATION

WARNING RISK OF ELECTRIC SHOCK OR FIRE

Grounding: Corded Units

In short Corded units must be plugged into a properly grounded outlet with the same plug configuration, with no adapter. The cord plug has built-in GFCI protection, and a damaged cord must be replaced with an identical or equivalent rated cord.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌⁠​​​‌​⁠​​‍⁠⁠‌⁠​‍‍⁠‍⁠‍‍⁠‌⁠⁠⁠​‌‍⁠⁠​

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (for spray systems only)‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌⁠​​​‌​⁠​​‍⁠⁠‌⁠​‍‍⁠‍⁠‍‍⁠‌⁠⁠⁠​‌‍⁠⁠​

If your unit is a corded unit, it has been supplied with a ground-fault circuit-interrupter(GFCI) built into the plug of the power-supply cord. This GFCI device provides additional protection from the risk of electric shock. Should replacement of the plug or cord become necessary, use only identical replacement parts that include GFCI protection.

If your unit is a corded unit, it is for use on a nominal circuit and has a grounding attachment plug. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this unit.

GROUNDING INSTRUCTIONS

If your unit is a corded unit, it must be grounded. If the unit should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This unit is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local electrical codes and ordinances.

WARNING RISK OF ELECTRIC SHOCK
Improper connection of the unit-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the unit by removing the ground pin on the plug – if the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

This unit comes with a grounded attachable extension cord. If damaged, replace with Kaivac® (OEM) cord, or if necessary an equivalent cord rated 120V, 15 amps, 3-wire, 14 GA. This cord must be attached and mechanically secured using the provided cord connector to use the unit.

Grounding: Battery Units

In short The charger on battery units must be grounded. Plug it into a properly grounded outlet that matches the plug, without an adapter and without removing the ground pin.

Batteries and chargers: make sure your charger is compatible with your batteries, and set its charging algorithm to your battery pack before you use it.

GROUNDING INSTRUCTIONS

The charger must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This unit is equipped with a cord having equipment grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING RISK OF ELECTRIC SHOCK
Improper connection of the unit-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the unit by removing the ground pin on the plug – if the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

This unit is for use on a nominal circuit and has a grounding attachment plug. Make sure that the unit is connected to an outlet having the same configuration as the plug. No adapter should be used with this unit.

Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 7, used with permission. SES ref PF-HROI-KWGY‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‌⁠​​​‌​⁠​​‍⁠⁠‌⁠​‍‍⁠‍⁠‍‍⁠‌⁠⁠⁠​‌‍⁠⁠​
1050M LMOF03_ONLINE (2026)Page 7 of 30
GROUNDING INFORMATION

GROUNDING INFORMATION (CONTINUED)

In short This page explains how to choose an extension cord of the right size for the unit using Table 1, and to use only three-wire outdoor cords with three-prong grounding receptacles. It also shows how to knot the unit cord and extension cord together so the connection stays firmly attached.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍​​​​‌​⁠​​‌​⁠‌‌⁠‌‌​⁠‌​​‌‍​​⁠‌‌‍⁠‍‌

Make sure your extension cord is in good condition and is the correct size for your unit. Table 1 shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gage number, the heavier the cord. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍​​​​‌​⁠​​‌​⁠‌‌⁠‌‌​⁠‌​​‌‍​​⁠‌‌‍⁠‍‌

Use only three-wire outdoor extension cords that have three-prong grounding receptacles that accept the unit’s plug.

WARNING! RISK OF ELECTRIC SHOCK OR FIRE. To reduce the risk of personal injury due to a loose electrical connection between the unit’s plug and extension cord, firmly and fully attach the unit plug to the extension cord. Periodically check the connection while operating the unit to ensure it is fully attached. Do not use an extension cord that provides a loose connection. A loose connection may result in overheating, fire, and increases the risk of a burning.

To reduce the risk of disconnection of the unit’s cord from the extension cord during operations:

  • Make a knot as shown in Figure 1 below:

Figure 1 - Method of securing the appliance cord to the extension cord set

Two drawings of looping cords. (A) The cord set, labeled CORD SET, and the appliance cord, labeled APPLIANCE CORD, are tied together in a knot below the unplugged plug and receptacle. (B) The plug and receptacle are connected above the same knot.
(A) TIE CORD AS SHOWN; (B) CONNECT PLUG AND RECEPTACLE

Table 1 - Minimum gauge for extension cords

Ampere ratingVoltsTotal length of cord
More than, ANot more than, A120 V7.62 m (25 ft)15.24 m (50 ft)30.48 m (100 ft)45.72 m (150 ft)
mm² (AWG)
06—0.82 (18)1.3 (16)1.3 (16)2.1 (14)
610—0.82 (18)1.3 (16)2.1 (14)3.3 (12)
1012—0.82 (18)1.3 (16)2.1 (14)3.3 (12)
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 8, used with permission. SES ref PF-6ED2-DWDT‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍​​​​‌​⁠​​‌​⁠‌‌⁠‌‌​⁠‌​​‌‍​​⁠‌‌‍⁠‍‌
1050M LMOF03_ONLINE (2026)Page 8 of 30
UNIT COMPONENTS

UNIT COMPONENTS

In short This page identifies the lettered parts of the machine from two views and lists the base unit accessories with their item numbers. Use the letters to match each part or accessory to its name.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍‌​​​‌​⁠​​​​⁠​‌⁠⁠⁠‍​‌‍‌⁠‌‌‌⁠​⁠​‌⁠‍
Two views of the machine, left side and right side, with letters A to V marking the vacuum head, battery housing, dump hose, caster, wheel, autovac spreader, autovac, spray gun, spray line, chemical jug, tool tray, thumb throttle, handle, fill lid, jug holder, chemical injector valve, hoses, side tool tray, vacuum hose, vacuum wand and squeegee brush head
KeyComponent
AVacuum Head
BBattery Housing
CDump Hose
DCaster
EWheel
FAutovac Spreader
GAutovac
HSpray Gun
ISpray Line
JChemical Jug
KTool Tray
LThumb Throttle
MHandle
NFill Lid
OJug Holder
PChemical Injector Valve
QAutovac Hose
RMixing Hose
SSide Tool Tray
TVacuum Hose
UVacuum Wand
VSqueegee Brush Head

BASE UNIT ACCESSORIES

Base unit accessories labeled A to L: spray gun, carpet glide tool, squeegee head brush, autovac spreader, metering tip kit, chemical cap, autovac, autovac mop pad, vacuum wand, dusting brush, upholstery tool and mesh filter
KeyAccessoryNumber
ASpray Gun#SUBGAKW
BCarpet Glide Tool#VT1
CSqueegee Head Brush#VBRUSH
DAutovac Spreader#ACAT06
EMetering Tip Kit#MTIPSNEW
FChemical Cap#CHCAPA
GAutovac#ACAT04
HAutovac Mop Pad#UWMP-26
IVacuum Wand#VAVW01
JDusting Brush#VT4
KUpholstery Tool#VT8
LMesh Filter#OBAGY
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 9, used with permission. SES ref PF-N66G-FIBK‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍‌​​​‌​⁠​​​​⁠​‌⁠⁠⁠‍​‌‍‌⁠‌‌‌⁠​⁠​‌⁠‍
1050M LMOF03_ONLINE (2026)Page 9 of 30
SETUP/BASIC OPERATION

SETUP/BASIC OPERATION

WARNING! DO NOT use a damaged unit or a unit with a damaged battery. Inspect battery, housing, plug, cord, splash cover (if applicable), and helmet (if applicable) for damage, including cracks, separation, dents, holes, missing, pieces, and fraying cord or wires. Check all cords, hoses, and spray lines for damage prior to use. If damage is found, do not continue until proper repairs are completed. If using a legacy unit equipped with a fabric splash cover, ensure the cover is flipped over the battery top. Newer battery models may also be equipped with a chemical-resistant plastic protective helmet and fabric splash cover, ensure cover is flipped over helmet top. DO NOT remove helmet if included.
WARNING! NEVER USE a damaged unit or a unit with damaged battery. Always check all hoses and spray lines damage prior to use. Using a damaged unit and failure to inspect it prior to use may result in electrical shock, fire, explosion, serious personal injury or even death.
CAUTION TIP HAZARD, DO NOT lean on unit if trolley bucket and/or vacuum tank are empty as unit may tip. Also use caution on rough surfaces to avoid tipping.
WARNING! NEVER spray unit directly with any liquids, water, hose, or spray gun. Corrosive liquids, water, and chemicals may enter battery or unit components which can result in an increased risk of fire and serious personal injury.
NOTICE Fill the trolley with water and recommended amount of Kaivac approved Chemicals. Follow the proper dilution instructions on bottles or dispenser. For accuracy and convenience, use Kaivac proportioned chemical packets. If a chemical is being used, use only KAIVAC APPROVED CHEMICALS AT the recommended dilution.

INSTALLING BATTERY AND CHARGING

In short This section covers battery-powered units only. Lower the battery into its housing, plug it into the vacuum motor plug, and charge it in the housing using the cord wrapped around the cleats.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍‍​​​‌​⁠​​​⁠⁠‌​⁠​​​⁠⁠⁠⁠‌​‍‌‌‌⁠​‌⁠‌

Batteries and chargers: make sure your charger is compatible with your batteries, and set its charging algorithm to your battery pack before you use it.

Battery units only‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍‍​​​‌​⁠​​​⁠⁠‌​⁠​​​⁠⁠⁠⁠‌​‍‌‌‌⁠​‌⁠‌

See Figures 1 - 4, page 11

  • Lower battery down into the battery housing.
  • To see battery charge, press the charge indicator on the top of the battery.
  • Connect the plug from the battery housing into the vacuum motor plug.
  • To charge the battery, keep the battery in the battery housing. Locate the cord wrapped around the cleats connected to the battery housing, plug into an outlet to begin charging .

PREPARING UNIT FOR USE

See Figures 5 - 9, page 11

  • The pump power cord is connected on the back panel of the spare water reservoir. Ensure this is connected to the battery housing power cord located on the back of the vac tank.
  • Ensure Vacuum motor is in place on the vacuum tank. Ensure top clasps are secured. Ensure float cage is in place and clean.
CAUTION RISK OF INJURY
Do not use if float cage is not in place.
  • Locate switch panel on vacuum head. This is used to operate the vacuum function.
  • Ensure vacuum tank clasps are secure. Locate tool tray on side of trolley bucket to place vacuum wand when not in use.
  • Unplug battery from charger if applicable. Avoid getting water on unit.
  • Inspect battery, housing, plug, cord, splash cover (if applicable), and helmet (if applicable) for damage, including cracks, separation, dents, holes, missing, pieces, and fraying cord or wires.

FILLING THE UNIT

In short Fill the unit with clean water and approved chemical, with the spigot closed. Fill the spare water reservoir with clean water only, and use a foam inhibitor if the cleaning product foams.

See Figures 9 - 13, page 12

Ensure spigot is closed before filling.

  • The spare water reservoir has a fill hose and lid. Fill as needed when using the spray gun.
NOTICE
  • DO NOT fill the spare water reservoir with chemical. Use clean water only. Note the location of the site tubes.
  • Fill in the designated opening near the water reservoir and vacuum tank.
NOTICE
  • If using a Chemical packet, pour desired Chemical packet into the designated fill area of the trolley bucket, and ensure proper dilution of chemical is used.
  • Note the location of the site tubes and gallon markings displayed for 5 to 8 gallons. For lesser quantity needs, the bottom of the label represents 2 gallons. For higher volume needs, the top of the label represents 10 gallons.
  • If using a cleaning product that foams, use a foam inhibitor to cut excess. Pour 2 capfuls of inhibitor in the Vacuum Hose with Vac running to coat inside of Vacuum Hose.
CAUTION Risk of motor damage
  • Foaming chemicals in tank may damage Vac Motor.

ACCESSORY ATTACHMENT USAGE

In short Accessory tools attach to the end of the vacuum wand by loosening and retightening the coupler nut, or directly into the yellow vacuum hose cuff. Keep the brass ring in the coupler nut in place.

See Figures 14 - 20, page 12

  • To attach different accessories to the end of the vacuum wand, start by loosening the coupler nut of the wand. Insert the accessory tool, and tighten the coupler nut.
  • Ensure the brass ring inside the coupler nut of the vacuum wand stays in place and does not get lost when changing accessories or taking apart.
  • To use accessories without the vacuum wand, push the desired accessory tool directly into the end of the yellow vacuum hose cuff connected to the side handle tube. Reconnect to tube when done with accessory use.
  • You may use the provided dusting brush tool to vacuum fans and high surfaces with the vacuum wand.
  • You may use the squeegee head brush head for stairways and surfaces such as tile and grout lines
  • You may use the upholstery tool for spot cleaning.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 10, used with permission. SES ref PF-VNMZ-33M2‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍‍​​​‌​⁠​​​⁠⁠‌​⁠​​​⁠⁠⁠⁠‌​‍‌‌‌⁠​‌⁠‌
1050M LMOF03_ONLINE (2026)Page 10 of 30
OPERATION
Battery pack being lowered by hand down the guide rail into the battery housing on the machine body, with arrow showing downward motion; callouts A battery pack, B battery housing, C guide rail
Fig. 1 - A - Battery pack, B - Battery Housing, C - Guide Rail
Close-up of the top of the battery pack showing the yellow cover with the charge indicator panel and an arrow pointing to the CHARGE INDICATOR
Fig. 2 - Battery Pack charge indicator
Machine with the battery housing installed showing the power cords: A C20 vacuum head power cord, B C19 battery housing power cord, C battery charging cord, D pump switch
Fig. 3 - A - C20 Vacuum head power cord, B - C19 Battery housing power cord, C - Battery charging cord, D - Pump switch
Close-up view of the cord connector at the machine with a circular magnified inset showing the plug and cord clipped in place
Fig. 4
Vacuum head lifted above the tank showing the vacuum motor, the float cage and float basket beneath it, and the locking clasps on the tank rim; callouts A to D
Fig. 5 - A - Vacuum Motor, B - Float Cage, C - Float Basket, D - Locking clasps
Top view of the vacuum head showing the vacuum motor switch panel with green I and red O buttons, callout A
Fig. 6 - A - Vacuum Motor Switch Panel
Lower part of the trolley and bucket showing the locking clasps (A) and the tool tray (B) at the base
Fig. 7 - A - Locking clasps, B - Tool tray
Hand pulling a latch with an orange arrow pointing left, beside a hand holding the battery charger plug and cord, with an orange arrow marking a spot on the cord to check for damage
Fig. 8 - Battery Charger plug. Check all cords for damage.
Trolley bucket spigot with the hose end in the closed position at the bottom of the bucket
Fig. 9 - Trolley bucket spigot "OFF" position.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 11, used with permission. SES ref PF-IQTP-GNJD‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​‍⁠​​​‌​⁠​​‌‍⁠⁠​‍‍⁠‍⁠​‌‌​​‌‌‍​‍⁠​⁠‌
1050M LMOF03_ONLINE (2026)Page 11 of 30
OPERATION
Machine with the fill port and sight tubes shown; a blue tube runs along the upper tank and a shorter tube near the lower tank, with an arrow pointing down to the fill port
Fig. 10 - Fill Port and Site Tubes.
Gloved hand holding a hose over the trolley bucket area of the machine, with a teal tool or hose end positioned at the opening
Fig. 11
Gloved hand pouring a blue packet of chemical into the trolley bucket on the machine
Fig. 12 - Proportioned Kaivac Approved chemical inside trolley bucket.
Spare water reservoir on the machine with a black arrow pointing to its round cap on top and a fill hose running down its side
Fig. 13 - Spare Water reservoir and fill hose.
Vacuum wand coupler assembly and squeegee head: A coupler nut with a rotation arrow, B coupler, C vacuum wand, D squeegee head
Fig. 14 - A - Coupler Nut, B - Coupler, C - Vacuum Wand, D - Squeegee Head
Brass ring with a yellow exclamation mark beside it, shown as the ring that sits inside the coupler nut
Fig. 15 - Brass Ring inside Coupler Nut.
Hose connection with an arrow pointing left: A orange vacuum hose yellow cuff, B black autovac hose, C yellow handle tube port
Fig. 16 - A - Vacuum Hose Yellow Cuff, B - Autovac Hose, C - Handle Tube Port
Two vacuum hoses with yellow cuffs: A yellow cuff, B corrugated vacuum hose, C desired accessory attached at the end of the hose
Fig. 17 - A - Vacuum Hose Yellow Cuff, B - Vacuum Hose, C - Desired Accessory
Dusting brush attached to a vacuum wand, reaching a high surface near a door frame to extract debris
Fig. 18 - Dusting Brush connected to vacuum wand to extract debris on high surface.
Squeegee head brush on a vacuum wand cleaning the edge of a stair step with debris being drawn in
Fig. 19 - Squeegee Head Brush connected to vacuum wand to extract debris on stairwars.
Upholstery tool connected to a vacuum hose with a yellow cuff, treating a wet spot with arrows showing suction
Fig. 20 - Upholstery Tool connected to vacuum hose for spot treatment.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 12, used with permission. SES ref PF-EBAN-GYSZ‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠​​​​‌​⁠​​‌⁠‌‍‌‌​​‌⁠​‍⁠‍‌​‍‌‍‌⁠‌⁠‌
1050M LMOF03_ONLINE (2026)Page 12 of 30
CARPET & DRY VACUUM OPERATION

CARPET & DRY VACUUM OPERATION

NOTICE Unit must have cleaning solution and water in trolley bucket during cleaning. Lack of liquid may cause premature product damage.

CARPET OPERATION

In short This section explains how to use the unit for carpet and dry vacuuming. Fill the unit, connect the vacuum hose, set the strap and thumb throttle to the carpet position, and make sure the mixing tube valve is ON before running the vacuum motor.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠‌​​​‌​⁠​​‌​​⁠​⁠‌‌​‌​⁠⁠⁠‌⁠⁠⁠⁠⁠‍‍‌​
  • Ensure unit is properly filled with appropriate amount of water and/or solution (Fig. 21).
  • Ensure vacuum hose is connected to the tube on the side of the handle (Fig. 22).
  • Lift the snap strap on the handle and ensure it is on the "CARPET" tab (Fig. 23).
  • Turn the thumb throttle handle counter clockwise to "CARPET/OFF" position (Fig. 23).
NOTICE
  • Locate the mixing tube valve and ensure it is in the "ON" position for dry vacuuming (Fig. 24).
  • Turn the vacuum motor ON (I)
  • Vacuum carpet as needed. For hard to reach areas, use provided accessories with vac hose or vac wand (Fig. 25).
  • Use the upholstery tool for spot cleaning as needed (Fig. 26).
  • Turn vacuum motor OFF (O) when job is complete.
  • For transport mode, lift the strap to "UP" position.
Trolley bucket filled with light blue water or cleaning solution, with the vacuum hose attached at the right side
Fig. 21
Vacuum hose connected to the tube on the side of the handle, with a yellow clip and an arrow pointing at the connection
Fig. 22
Handle with the snap strap on the yellow CARPET tab and an arrow showing the thumb throttle handle being turned to the CARPET/OFF position; the vacuum hose and wheel are shown below
Fig. 23
Mixing tube valve with a yellow lever on the hose, above two valve handle symbols: OFF for wet vac and ON for dry vac
Fig. 24
Vacuum hose with a tool picking up debris from the floor under a bench
Fig. 25
Hand holding the upholstery tool on a yellow hose over a blue spill on carpet
Fig. 26
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 13, used with permission. SES ref PF-WQ5I-LNGN‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠‌​​​‌​⁠​​‌​​⁠​⁠‌‌​‌​⁠⁠⁠‌⁠⁠⁠⁠⁠‍‍‌​
1050M LMOF03_ONLINE (2026)Page 13 of 30
HARD FLOOR & WET VAC OPERATION

HARD FLOOR & WET VAC OPERATION

NOTICE Unit must have cleaning solution and water in trolley bucket during cleaning. Lack of liquid may cause premature product damage.

HARD FLOOR OPERATION

In short This section explains how to set up and run the unit for hard floor cleaning and wet vacuuming. Fill the unit, connect the vacuum hose, set the strap and thumb throttle handle to HARD FLOOR, make sure the mixing tube valve is OFF, then turn the vacuum motor on and work from the rear of the area toward the front.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠‍​​​‌​⁠​​‍⁠​⁠⁠‌⁠​‌‌‌‌‍​‍‍⁠​⁠⁠‍‌​‌
  • Ensure unit is properly filled with appropriate amount of water and/or solution (Fig. 27).
    Trolley bucket of the unit filled with blue cleaning solution, seen from the side with its caster wheels
    Fig. 27
  • Ensure vacuum hose is connected to the tube on the side of the handle (Fig. 28).
    Vacuum hose with an orange cuff connected to a yellow fitting on the tube at the side of the handle, with an arrow pointing at the connection
    Fig. 28
  • Lift the snap strap on the handle and ensure it is on the “HARD FLOOR” tab (Fig. 29).
  • Turn the thumb throttle handle counter clockwise to “HARD FLOOR” position (Fig. 29).
    Handle with the snap strap lifted onto the HARD FLOOR tab and a curved arrow showing the thumb throttle handle turned counter clockwise to the HARD FLOOR position
    Fig. 29
NOTICE
  • Locate the mixing tube valve and ensure it is in the “OFF” position for wet vacuuming (Fig. 30).
    Mixing tube valve on the tube, with a diagram of the valve handle in the OFF position for wet vac and the ON position for dry vac
    Fig. 30
  • Turn the vacuum motor ON (I)
  • Beginning at the rear of the area, begin dispensing solution, moving towards the front of the area (Fig. 31).
    Vacuum wand picking up solution from the floor, with four top-view diagrams of the operator working from the rear of the area toward the front, leaving a wet path
    Fig. 31
  • Turn Spigot clockwise to the “OFF” position when job is complete.
  • For extra detailing, vacuum floor surface diagonally to grout lines, reaching under shelves, seating etc. (Fig. 32).
    Vacuum tool on a grout-lined tile floor with orange arrows showing diagonal movement across the grout lines
    Fig. 32
  • Slap & Tap: Once Vacuuming is complete, keep motor running. Slap Vacuum Wand on floor 3-4 times to dislodge debris from squeegee head. Then, invert Wand and Tap 4-5 times to dislodge any fluids or substance from Wand.
  • Turn vacuum motor OFF (O) when job is complete.
  • For transport mode, lift the strap to “UP” position.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 14, used with permission. SES ref PF-PAVN-DV3S‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠‍​​​‌​⁠​​‍⁠​⁠⁠‌⁠​‌‌‌‌‍​‍‍⁠​⁠⁠‍‌​‌
1050M LMOF03_ONLINE (2026)Page 14 of 30
SPRAY OPERATION

SPRAY OPERATION

WARNING! NEVER spray unit directly with any liquids, water, hose, or spray gun. Corrosive liquids, water, and chemicals may enter battery or unit components which can result in an increased risk of fire and serious personal injury.
CAUTION! NEVER point the spray gun at yourself or others. Always use proper personal protection equipment and only point the sprayer at and/or spray the intended object. Failure to do so may result in personal injury
In short This section explains how to prepare the chemical jug, set the valves and use the spray gun. Chemical is applied in low pressure only, then cleared from the spray line before rinsing with fresh water in high pressure.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠⁠​​​‌​⁠​​‍‍‍‍⁠‍‌‌‌⁠⁠‌⁠‌​‌⁠​⁠​‍​⁠‌

SPRAY OPERATION

  • If using unit with chemical, prepare the cleaning chemical, make sure the Draw Tube is inserted into the Chemical Jug. Insert the Metering Tip as shown (see Metering Tip Selection Chart on the Metering Tip Bag). Then, screw the Chemical Cap onto the Chemical Jug and make sure the clear Chemical Line is connected to the Chemical Cap (Fig. 33).
  • Place the chemical jug into the jug holder located on the spare water reservoir (Fig. 34).
  • Ensure reservoir is filled with clean water before using spray gun.
  • To use spray gun with chemical, turn the injector valve on the jug holder to "ON" position as shown (Fig. 35).
  • To turn Spray Gun off or on, switch the valve connected to Spray Gun. The Spray Gun is connected to the Pressure Hose (Fig. 36).
  • Operate the Spray Gun by pulling the nozzle out and twisting for low pressure pinpoint or fan spray. Pull nozzle back for high pressure pinpoint or fan spray. Chemicals applied in the Low Pressure setting only. Chemicals must be cleared from the Spray Line prior to High Pressure rinsing. To do this, turn OFF the Chemical Valve, then spray in Low Pressure settings for 15 seconds (Fig. 37).
  • Turn the "PUMP" switch located on the battery housing ON (I) to begin using after preparing. Spray intended object with chemical in low pressure, and then turn the chemical valve OFF and clean with fresh water in high pressure (Fig. 38).
Chemical jug with draw tube and cap, labeled A to E: A metering tip, B chemical cap, C draw tube, D chemical jug, E clear chemical line; arrows show the tip and line connecting to the cap
Fig. 33
Chemical jug seated in the jug holder on the spare water reservoir, with a clear line running from the cap to the injector valve
Fig. 34
Injector valve on the jug holder above the reservoir, shown in position for turning chemical on
Fig. 35
Two views of the valve connected to the spray gun, with the handle across the line marked OFF and turned along the line marked ON
Fig. 36
Spray gun with the nozzle twisted: Low Press. and High Press. positions and Pinpoint Spray and Fan Spray settings, with arrows showing twist direction
Fig. 37
Battery housing with an arrow pointing to the red and green PUMP rocker switch on the side
Fig. 38
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 15, used with permission. SES ref PF-NUVR-6MOA‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​​⁠⁠​​​‌​⁠​​‍‍‍‍⁠‍‌‌‌⁠⁠‌⁠‌​‌⁠​⁠​‍​⁠‌
1050M LMOF03_ONLINE (2026)Page 15 of 30
DAILY & GENERAL MAINTENANCE

DAILY & GENERAL MAINTENANCE

In short The unit should be checked, emptied and cleaned after each use, with the unit turned OFF unless specified. The page covers emptying the vacuum tank, cleaning the unit and its filters, and replacing mop pads and squeegee blades.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​​​​​‌​⁠​​‌‍​​​​‌‍‍‌⁠‌⁠‌‌​‌⁠​⁠‌‍‌​

The unit should be checked, emptied, and cleaned after each use.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​​​​​‌​⁠​​‌‍​​​​‌‍‍‌⁠‌⁠‌‌​‌⁠​⁠‌‍‌​

Unit should be turned OFF (O) unless specified.

EMPTYING THE VACUUM TANK

  • If the Vacuum Motor shuts off before the job is complete, the Vacuum Tank may be full and need to be emptied. Lift the Vacuum Head to check liquid level inside the Vacuum Tank.
  • To begin the dumping process, you must first press down on the Cap and turn counter-clockwise (Fig. 34).
  • Vacuum tank cap with arrows and text PRESS DOWN and TURN showing how to press the cap down and turn it counter-clockwise
    Fig. 34
  • Once cap is removed, lower Dump Hose into appropriate sink/drain (Fig. 35).
  • Yellow vacuum tank with the dump hose lowered into a sink, liquid draining out
    Fig. 35
NOTICE To prevent an accidental spill or overflow from the Dump Hose, be careful to keep hose end upright until it is over sink/drain.

CLEANING UNIT

  • When work is complete, vacuum excess cleaning solution from the bucket for 5 seconds to clean out and degrease the Vacuum Hose (Fig. 36).
  • Trolley with vacuum tank; vacuum hose held in the bucket to vacuum cleaning solution for 5 seconds
    Fig. 36
  • Alternatively, you can also turn the Vacuum ON (I) and dispense solution into Vacuum Hose to clean Hose and Tank.
  • Rinse Vacuum Tank thoroughly at clean-up sink, preferably with hot water. Rinse out Trolley Bucket (Fig. 37).
  • Vacuum tank on trolley being rinsed with a spray hose, water running down into the trolley bucket
    Fig. 37

CLEANING UNIT FILTERS

  • Lift the Vacuum Head. Clean and spray the Float Cage located inside the Vacuum Head. Ensure Float Cage is in place. Clean Float Cage regularly Do not use if Float Cage is not in place (Fig. 38).
  • Vacuum head lifted off and the float cage inside being sprayed with a water spray gun
    Fig. 38
  • If unit contains mesh Filter Bag located inside the Vacuum Tank, before starting each new cleaning process, remove Filter Bag, dump any debris out, spray clean, and then replace back into the Filter Bag Frame (Fig. 39).
  • Mesh filter bag in its frame being sprayed clean with a water spray gun
    Fig. 39
  • Rinse plastic finger filter and foam filter inside Trolley Bucket following to clear debris (Fig. 40).
  • Plastic finger filter and foam filter inside the trolley bucket
    Fig. 40

SQUEEGEE BLADES & ACCESSORIES

  • Replace mop pads by aligning with the spreader, and folding under (Fig. 41).
  • Mop pad being aligned with the spreader (Align pad) and folded under (Fold under)
    Fig. 41
  • Check for worn squeegee blades. Worn blades cause streaking and loss of vacuum suction.
  • Replace with new every 6-8 weeks. Ensure squeegee blades are replaced with the ribbed portion facing outwards (Fig. 42).
  • Squeegee tool with an enlarged circle showing the blade with its ribbed portion facing outwards
    Fig. 42
  • Clean off accessories and build-up on parts and tools.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 16, used with permission. SES ref PF-C6TR-722G‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​​​​​‌​⁠​​‌‍​​​​‌‍‍‌⁠‌⁠‌‌​‌⁠​⁠‌‍‌​
1050M LMOF03_ONLINE (2026)Page 16 of 30
UNIT & MAINTENANCE

UNIT & MAINTENANCE

In short This section lists what to check or do for each part of the unit, from the floor squeegee to the battery and splash cover. Always unplug the unit before servicing or inspecting it.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​‌​​​‌​⁠​​⁠⁠​​​​‌​‌⁠⁠⁠​‌​‍‍‌‌‌⁠‍​⁠
Warning label with an orange WARNING header and a yellow triangle with a lightning bolt, reading RISK OF ELECTRIC SHOCK OR FIRE, with the text Always unplug unit before servicing unit or inspecting
WARNING! RISK OF ELECTRIC SHOCK OR FIRE
Always unplug unit before servicing unit or inspecting.
ITEMPROCEDURE
Floor Squeegee
  • Check condition of squeegee blades and wheels on the floor tool.
  • Rough floor surfaces will cause the blades and wheels to wear out more quickly Replace as necessary.
Spray Gun
  • Check spray pattern. If spray pattern will not pinpoint, clean orifice by removing it with an Allen wrench and flushing. Replace if needed.
  • If nozzle becomes difficult to move from high to low pressure, lubricate nozzle with lithium grease.
Pressure Hose
  • Wipe clean after each use.
  • Check for cuts or frays in the hose jacket, particularly at the end of the fittings. Replace hose if cuts are found.
Water Tank
  • Check condition of filter in water tank. Clean as needed.
  • Empty the water tank to prevent mildew and bacteria growth. Empty tank by dipping the vacuum hose into the water tank and transferring the water to the vacuum tank.
Vacuum Tank
  • Empty and flush vacuum tank.
  • Clean and disinfect.
  • Check the float shutoff screen to be sure it is not blocked or dirty. A plugged filter screen restricts airflow and results in reduced suction.
Leaks
  • Be alert for leaks around hoses, fittings, spray wand, tanks or elsewhere.
  • Discontinue use until leaks are repaired.
Electrical System
  • The ground fault circuit interrupter (GFCI) must be tested before each use.
  • Electrical cord must be inspected for tears or cuts in the insulation.
  • Inspect plug and be sure ground pin is in place.
Vacuum Wand
  • Use a wire or coarse brush with acid cleaner to remove residue from threads on the coupling and coupling nut. Apply grease when done.
HEPA Filter
  • Replace every 3-6 months depending on use.
Float Cage
  • Ensure cage is sprayed and cleaned daily to remove debris.
Battery Maintenance
  • Inspect battery, plugs, cords, splash cover (if included), and chemical-resistant plastic protective helmet (if included) before charging and after charging.
  • Charge and store battery indoors.
  • If included, the battery splash cover must remain in place. Without the battery splash cover, the battery housing may become damaged which may cause the battery to malfunction, which can result a fire, explosion, personal injury, and/or property damage.
  • Always keep helmet affixed to top of battery if your battery is so equipped.
  • To view the battery, temporarily move the splash cover (if included). Replace the splash cover after inspection. Do not use unit if battery shows any damage, including cracks, dents, holes, fraying, or missing pieces.
  • Once your battery run time is less than 55% (50 minutes for non-quick change and 30 minutes for quick change batteries), contact Kaivac to replace your battery. Regardless of run time, replace your battery after 4 years. Consult Kaivac.com for information on recycling your old battery.
  • DO NOT attempt to repair, service or modify the batteries or charger. Contact Kaivac Technical Support with any issues.
  • DO NOT use or store the NTC Unit, Omniflex Unit, or battery in refrigerated areas, in environments when the battery is in direct contact with liquids, or near flammable or combustible materials.
  • DO NOT charge or store battery for extended time (1 month or more) in temperatures below 40°F (4°C).
  • DO NOT use a battery or appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury.
  • If unit is smoking or sparking, move outside to a fire-safe location immediately. If possible, disengage battery from unit, notify management, and call Kaivac Technical Support at 800-287-1136, Ext. 2
Splash Cover (if applicable)
  • Inspect splash cover for damage.
  • Clean and dry the splash cover.
  • Be sure the splash cover is secure.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 17, used with permission. SES ref PF-ZMJE-LQYW‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​‌​​​‌​⁠​​⁠⁠​​​​‌​‌⁠⁠⁠​‌​‍‍‌‌‌⁠‍​⁠
1050M LMOF03_ONLINE (2026)Page 17 of 30
ELECTRICAL DIAGRAM

ELECTRICAL DIAGRAM

In short This page shows the wiring diagram for the machine: the battery housing assembly with the 36VDC battery pack and 36V DC charger, the 36 VDC pump motor, and the 36 VDC vacuum motor with its switch.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​‍​​​‌​⁠​​‌⁠⁠⁠​⁠​‌‌⁠‌‌​⁠‌‌‌⁠‍‌‌‍⁠​

Batteries and chargers: make sure your charger is compatible with your batteries, and set its charging algorithm to your battery pack before you use it.

Electrical wiring diagram. The battery housing assembly contains the 36VDC battery pack with BMS, charge indicator and USB port, an ICT unit, a 36V DC charger (input 120 VAC 1.4 Amps, output 42VDC 4A max), and a pump switch. Colored wires (red, black, green, white, orange; 12, 14, 16, 18 and 20 AWG) connect to C19 and C20 IEC connectors on 3-wire SJT cables, a 2-wire SVT cable with 120V standard NEMA 1-15P wall plug, a 36 VDC pump motor, and, in a separate box on the right, a vac switch and a 36 VDC vacuum motor.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 18, used with permission. SES ref PF-Z5J5-MEF7‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​‍​​​‌​⁠​​‌⁠⁠⁠​⁠​‌‌⁠‌‌​⁠‌‌‌⁠‍‌‌‍⁠​
1050M LMOF03_ONLINE (2026)Page 18 of 30
TROUBLESHOOTING CLOGS

TROUBLESHOOTING CLOGS

In short This page shows where clogs can occur on the right side of the unit, with the clog areas circled. Check the vacuum hose, the hose connections, the vacuum tank inlet and the yellow mesh filter in turn.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​⁠​​​‌​⁠​​‍⁠⁠‍‍​‌​‍‍⁠‌​​‌​⁠⁠‍⁠‍‌‍​
Right side view of the unit with the vacuum hose running from the squeegee head at the lower left, along the base and up to the handle and vacuum tank. Three orange circles mark the clog areas: the hose connection at the upper left near the handle, the mixing tube connection at the center, and the squeegee head hose connection at the lower left.
RIGHT SIDE VIEW

Clog Areas of the unit are circled above

  1. Check the Vacuum Hose for clogs with the Vacuum Motor running.
    Starting at the squeegee head and working forward to the vacuum tank, pull off the Vacuum Hose one connection at a time to find a clog in the Vacuum Hose.
  2. Check Vac Hose Connection on Handle.
  3. Check Vac Hose connection at the Mixing Tube.
  4. Check for clog at inlet of the Vacuum Tank.
    Check for clog at the inlet of Vacuum tank circled above.
  5. Check the yellow mesh filter inside the tank to see if full. Empty and replace if applicable.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 19, used with permission. SES ref PF-SLKU-X436‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌​⁠​​​‌​⁠​​‍⁠⁠‍‍​‌​‍‍⁠‌​​‌​⁠⁠‍⁠‍‌‍​
1050M LMOF03_ONLINE (2026)Page 19 of 30
TROUBLESHOOTING

TROUBLESHOOTING

WARNING! Always unplug unit before inspecting or servicing.
In short This table lists problems by area (electrical, vacuum system, blow dry system) with the possible cause and the fix for each. Always unplug the unit before inspecting or servicing, and turn the unit off immediately if there is an electrical burning smell.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌‌​​​​‌​⁠​​​​‍⁠‌​‍‌‍‌​‌‌‍⁠‍‍‍‍​​‌⁠​
AREAPROBLEMPOSSIBLE CAUSEREMEDY
ElectricalNo Power to pump or vac motorUnit not plugged inPlug unit in
Switch not “on”Check switches for “on”
GFCI trippedTest and reset GFCI
Building circuit overloadedCheck and reset circuit
Switch wires looseDisconnect power and check for loose wire
Connections looseDisconnect power and check for loose wire under panel
Electrical burning smell
WARNING! RISK OF FIRE, SERIOUS INJURY, OR DEATH
TURN UNIT OFF IMMEDIATELY.
Vac motor brushes wornRemove vac motor and repair
Vac motor hung upRelease pressure on hose and jog vac switch, or replace
Pump motor hung upRelease pressure on hose and jog pump switch, or replace
Vacuum SystemNo/Weak vacuumVac tank fullEmpty vac tank
Squeegee blades or wheels wornReplace wheels or blades and check periodically
Float shutoff screen dirtySpray off float screen to clean
Float ball stuckTap float and release/clean
Damaged hoseCut and repair/replace
Dump hose plug missingContact dealer and replace
Access lid not rightTighten lid hand tight
Vacuum hose pluggedFlush hose to remove debris
Too much liquid in vac hoseAllow air in when vacuuming
Vac hose still wrappedUnwrap vac hose fully
Exhaust pluggedClean exhaust port and HEPA filter
Leak in vac tankIf repairable, clean and dry affected area and seal with silicone
HEPA filter cloggedRemove HEPA filter and clean
Moisture from exhaustVac tank fullDump vac tank
Float shutoff missingReplace
Excessive foam in vac tankUse defoamer
Blow Dry SystemNo air flowHose disconnectedReconnect hose
Moisture from exhaustWater in blow hoseDry blow line
Suction, not blow actionVacuum hose connected to vac tankReconnect to vac motor exhaust hose
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 20, used with permission. SES ref PF-EK7E-4WSZ‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌‌​​​​‌​⁠​​​​‍⁠‌​‍‌‍‌​‌‌‍⁠‍‍‍‍​​‌⁠​
1050M LMOF03_ONLINE (2026)Page 20 of 30
TROUBLESHOOTING

TROUBLESHOOTING

In short This table lists problems with the high pressure system and the chemical injection system, with the possible causes and the fix for each. Always unplug the unit before inspecting or servicing.‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌‌‌​​​‌​⁠​​​​‌​⁠⁠‍‌​‌‍‍⁠‌​​​‍‍‍‌‍⁠‍
WARNING Always unplug unit before inspecting or servicing. RISK OF ELECTRICAL SHOCK, FIRE, SERIOUS INJURY, OR DEATH
AREAPROBLEMPOSSIBLE CAUSESOLUTION
High Pressure SystemNo water from pump or low pressureOut of waterFill water tank
Gun nozzle pluggedRemove orifice with Allen wrench and clean
Air in pump (vapor lock)Use power prime technique
Gun orifice missingReplace orifice
Water tank filter pluggedClean tank and filter
In-line bowl filter pluggedRemove filter cover and clean
Bowl filter lid looseGently tighten bowl cover
Pressure hose damagedRepair or replace
Quick disconnect leakingTighten or replace
Injector pluggedRemove safety cap from chemical and blow small amounts of compressed air into line
Pulse hose damagedRepair or replace
Regulator failedReplace
Hose kinkedUnkink and check for damage
Seals in pump need replacedRemove and replace seals
Bad fan pattern or pinpoint pattern on gunDebris in nozzleRemove orifice with Allen wrench and clean
Orifice damagedRemove and replace
Chemical Injection SystemNo chemical flowOut of chemicalRefill chemical
Safety cap not secureCheck safety cap/tighten
Chemical valve “off”Check on/off valve
Safety cap pluggedReplace cap
Spray gun in wrong modeMake sure gun nozzle is pulled out away from gun chemical mode
Metering tip pluggedCheck metering tip for clog
Injector pluggedRemove safety cap from chemical and blow small amounts of compressed air into line
Air entering systemCheck for air entering system around chemical lines or injector
Injector installed backwardsIf fluttering or pulsing sound can be heard while spraying or when unit is running, it is possible that your injector is in backwards. Remove; reinstall.
Kink in chemical lineReplace chemical line
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 21, used with permission. SES ref PF-EID3-KHYR‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌‌‌​​​‌​⁠​​​​‌​⁠⁠‍‌​‌‍‍⁠‌​​​‍‍‍‌‍⁠‍
1050M LMOF03_ONLINE (2026)Page 21 of 30
TROUBLESHOOTING

TROUBLESHOOTING

AREAPROBLEMPOSSIBLE CAUSESOLUTION
Chemical Injection System continuedNot enough chemicalMetering tip pluggedRemove and clean
Not enough chemicalWrong metering tipCheck and replace per chart
Chemical line blows off safety capDebris in injectorRemove safety cap from chemical and blow small amounts of compressed air into line
Water back flows into chemical bottleBad seat on injector check valveCheck injector o-ring or replace
Water back flows into chemical bottleBad safety capReplace safety cap
Dump SystemDump hose will not empty tankDump hose cap not removedRemove cap
Clog in bottom of tankTip dump contents, remove debris
Dump hose leaksHose cutIf leak is less than 4" from tank side, cut and reattach, or replace
Clamp looseTighten hose clamp
Dump cap missingReplace cap
Wheels and CastersWheels will not roll; rubbingFlat tiresInflate tires to 30 p.s.i.
Debris wrapped around axleCheck for debris on axle
Bearings tightGrease bearings
Wheels too loose on axleRemove wheel, add washers to take up slack
Bearings falling outReplace bearing assembly
Squeegee HeadFloor streaksWorn blades or wheelsReplace wheels and/or blades
Squeegee head does not easily rotate when installed on wandBrass ring on wand not in grooveLoosen coupling nut and re-position head on groove
Coupling nut too tightLoosen 1/2 turn
Head will not stay on wandCoupling nut crackedReplace
Brass ring wornReplace
Premature blade wearSqueegee wheels wornCheck wheels for wear/replace
Sucks to the floor too tightlySqueegee wheels wornCheck wheels for wear/replace
Battery
WARNING! RISK OF FIRE, EXPLOSION, AND SERIOUS INJURY, OR DEATH
Sparks/Burning/Fire/Smoke
STOP USE IMMEDIATELY
Damage to battery or chargerStop use immediately. Disconnect battery from charger, if possible. Unplug charger, if possible.
Source: Kaivac 1050M Operator Manual LMOF03_ONLINE Rev. 2026, page 22, used with permission. SES ref PF-CNPO-KZQC‌‌​⁠‍‍​‍‌‌‍​‌​​​‍​‌‍​​​​​‌‌‍​​​‌​⁠​​‍​‌​‌⁠​⁠​‌‌‌​‌‍​​‍‌‌⁠⁠​⁠
1050M LMOF03_ONLINE (2026)Page 22 of 30

Kaivac and KaiVac are trademarks of Kaivac, Inc. Southeastern Equipment & Supply is an independent dealer.

Not Sure Which Machine Fits Your Floors?

Talk to a real SES tech about new, demo or certified reconditioned options, parts and service.

© 2026 Southeastern Equipment and Supply, Inc. All Rights Reserved.

Visa Discover AMEX Mastercard