New Aerospace America Full Feature 600 Mag
Our Take (from the SES Sales Team)
“Some jobs, especially abatement and healthcare work, call for an air scrubber that warns you when the filters are loaded. The 600 Mag Full Feature does that with a red high-pressure warning light and an audible alarm, on top of the Minihelic pressure gauge, push-button circuit breaker and two-speed rocker switch. Underneath, it is the same 600 Mag: a 1.0 hp two-speed motor and direct drive blower rated at 625 CFM on high and 425 CFM on low per the spec sheet, in an aircraft-grade aluminum cabinet that weighs 80 lb and rolls on two swivel and two rigid casters. The three filter stages are all 16 x 16 in, finishing with a 6 in deep HEPA, and the replacement filters are easy to keep on the truck. The 12 in exhaust takes flex duct for negative air. It draws 9.0 amps at 110 V, so plan circuits before you run several on one floor. Aerospace lists all of its electrical components as UL listed or UL recognized.”
The 600 Mag with a full-filter alarm
The Aerospace America Aeroclean 600 Mag Full Feature (model 9145FF) is a two-speed HEPA air scrubber with an audible and visual high-pressure alarm. It is built for asbestos and lead abatement, mold remediation, healthcare construction and other jobs where the crew needs a clear warning when the filters are loaded.
A 1.0 hp motor and direct drive blower move 625 CFM on high and 425 CFM on low through three stages of 16 x 16 in filters. The aircraft-grade aluminum cabinet is made in Bay City, Michigan.
Condition: New.
What you get
A full-feature control panel
Full Feature or standard 600 Mag?
Features
Ready for spec-driven jobs
- ✓Red high-pressure warning light with audible alarm
- ✓Two-speed operation: 625 CFM high, 425 CFM low
- ✓12 in exhaust for flex duct and negative air setups
- ✓Two swivel and two rigid casters with two top handles
- ✓Aircraft-grade aluminum cabinet, made in the USA
Choosing a unit
How the 600 Mag Full Feature compares
| Aerospace unit | Airflow (high / low) | Speed control | Amp draw | Weight |
|---|---|---|---|---|
| 500 Variable (#9150) | 100–575 CFM | Variable | 2.1 A | 44 lb |
| 600EV (#9160) | 0–550 CFM | Variable | 1.67 A | 32 lb |
| 600 Mag (#9145) | 625 / 425 CFM | Two-speed | 9.0 A | 80 lb |
| 600 Mag Full Feature (#9145FF) (this unit) | 625 / 425 CFM | Two-speed, filter alarm | 9.0 A | 80 lb |
| Aero 1000V (#1000V) | Up to 1,000 CFM | Variable | 5.5 A | 70 lb |
| 2000 Turbo (#9100) | 2,500 / 2,100 CFM | Two-speed | 15 A | 116 lb |
Figures are from each unit’s Aerospace America spec sheet. Full Feature versions with a filter alarm are also offered for the 600EV, 600 Mag and 1800.
Specifications
Aeroclean 600 Mag Full Feature at a glance
| Models | Aeroclean 600 Mag Full Feature |
|---|---|
| Airflow | 625 CFM high (17.7 m³/min); 425 CFM low (12.0 m³/min) |
| Power | 110 V, 9.0 A |
| Motor | 1.0 hp, two-speed |
| Blower | 2000 rated direct drive |
| 1st stage filter | 16 x 16 x 1/2 in pre-filter (9145-01) |
| 2nd stage filter | 16 x 16 x 1 in secondary (9145-02) |
| 3rd stage filter | 16 x 16 x 6 in HEPA (9145-03) |
| Instrumentation | Minihelic pressure gauge, push-button circuit breaker, two-speed rocker switch, red high-pressure warning light with audible alarm |
| Exhaust | 12 in (30 cm) |
| Sound level | 67–75 dB at 5 ft (1.5 m) |
| Handles / casters | 2 handles on top; 2 swivel and 2 rigid casters |
| Dimensions (L x W x H) | 31 x 18 x 20 in (79 x 46 x 51 cm) |
| Electrical | All components UL listed and UL recognized |
| Weight | 80 lb (36.3 kg) |
| Model Numbers | 9145FF (Aeroclean 600 Mag Full Feature) |
Technical specs may include optional equipment that is not included with all units.
Questions
Aeroclean 600 Mag Full Feature: common questions
What does the Full Feature panel add?
A red high-pressure warning light with an audible alarm. Aerospace’s manual describes it as indicating that the filters are full and need servicing.
Which replacement filters does it use?
Aerospace part 9145-01 (16 x 16 in pre-filter, case of 40), 9145-02 (16 x 16 in ring panel, case of 24) and 9145-03 (16 x 16 x 6 in HEPA). A 16 x 16 x 2 in pleated carbon filter (9145-04) is available for odors.
How often do the filters need changing?
Aerospace America’s owner’s manual says to change the first-stage pre-filter daily when the unit runs around the clock, check the second-stage ring filter each time and change it weekly or as needed, and plan on replacing the HEPA filter about every 350 hours of use. The pressure gauge on the panel tells you when the HEPA is loading up.
What extension cord should I use?
Aerospace calls for 12 gauge or heavier extension cords, no longer than 100 ft for 1 hp and larger units. Plug each air scrubber directly into its own power source rather than into another unit.
Not sure the 600 Mag Full Feature is the right size for your job?
Tell our team about the space, the containment and how long the job will run, and we will help you pick the right air scrubber and filters.