| Air Capacity | 1000 C.F.M. High Speed |
| Power | 110 Volt at 5.5 Amps |
| Motor | 1/2 H.P. Motor, Variable Speed |
| Blower | 2000 AMCA Rated Direct Drive Blower |
| Filters | 1st Stage: 16 x 16 x 1/2 Pre Filter 2nd Stage: 16 x 16 x 1 Secondary 3rd Stage: 16 x 16 x 6 HEPA |
| Handles | Two handles on top of unit |
| Casters | 2 Swivel, 2 Rigid for E-Z Mobility |
| Weight | 70 lbs |
New Aerospace America 1000CFM Variable Speed
Our Take (from the SES Sales Team)
“The Aero 1000V fills the gap between the compact 600-class units and the big 2,000 CFM machines. Aerospace rates it at 1,000 CFM on high, and because the 1/2 hp motor is variable speed, you can turn it down for smaller rooms or quieter work instead of choosing between just high and low. It runs on 5.5 amps at 110 V, which is light for the airflow, so you can usually run more units per circuit than with a 1 hp machine. At 70 lb with two handles on top and two swivel and two rigid casters, it is easy for one person to roll into place and lift into a van. The cabinet is aircraft-grade aluminum, and the blower is a 2000 AMCA rated direct drive unit. Filtration is three stages at 16 x 16 in: a 1/2 in pre-filter, a 1 in secondary and a 6 in deep HEPA. It is a strong all-around pick for restoration and remodel crews who want one air scrubber that scales to the job.”
1,000 CFM of variable speed HEPA filtration
The Aerospace America Aero 1000V (model 1000V) is a variable speed HEPA air scrubber for restoration, remodeling, mold remediation and construction dust control. A 1/2 hp variable speed motor drives a 2000 AMCA rated direct drive blower for up to 1,000 CFM on high.
The cabinet is aircraft-grade aluminum for durability and lower weight, and it is made in Bay City, Michigan. Three stages of 16 x 16 in filters finish with a 6 in deep HEPA filter.
Condition: New.

What you get
Big airflow on a light power draw
Why variable speed helps
Features
One unit that scales to the job
- ✓Variable speed control up to 1,000 CFM
- ✓Light 5.5 A draw at 110 V for its airflow
- ✓2000 AMCA rated direct drive blower
- ✓Two swivel and two rigid casters with two top handles
- ✓Aircraft-grade aluminum cabinet, made in the USA
Choosing a unit
How the 1000V compares
| Aerospace unit | Airflow (high / low) | Speed control | Amp draw | Weight |
|---|---|---|---|---|
| 500 Variable (#9150) | 100–575 CFM | Variable | 2.1 A | 44 lb |
| 600EV (#9160) | 0–550 CFM | Variable | 1.67 A | 32 lb |
| 600 Mag (#9145) | 625 / 425 CFM | Two-speed | 9.0 A | 80 lb |
| Aero 1000V (#1000V) (this unit) | Up to 1,000 CFM | Variable | 5.5 A | 70 lb |
| 2000 Turbo (#9100) | 2,500 / 2,100 CFM | Two-speed | 15 A | 116 lb |
Figures are from each unit’s Aerospace America spec sheet. Full Feature versions with a filter alarm are also offered for the 600EV, 600 Mag and 1800.
Specifications
Aero 1000V at a glance
| Models | Aero 1000V |
|---|---|
| Airflow | 1,000 CFM high speed (28.3 m³/min) |
| Speed control | Variable speed |
| Power | 110 V, 5.5 A |
| Motor | 1/2 hp, variable speed |
| Blower | 2000 AMCA rated direct drive |
| 1st stage filter | 16 x 16 x 1/2 in pre-filter |
| 2nd stage filter | 16 x 16 x 1 in secondary |
| 3rd stage filter | 16 x 16 x 6 in HEPA |
| Handles / casters | 2 handles on top; 2 swivel and 2 rigid casters |
| Dimensions (L x W x H) | 31 x 18 x 20 in (79 x 46 x 51 cm) |
| Construction | Aircraft-grade aluminum, made in the USA |
| Weight | 70 lb (31.8 kg) |
| Model Numbers | 1000V (Aero 1000V) |
Technical specs may include optional equipment that is not included with all units.
Questions
Aero 1000V: common questions
How much air does the 1000V move?
Aerospace rates it at 1,000 CFM on high speed. The variable speed motor lets you run it lower for smaller spaces.
How much power does it draw?
Aerospace rates it at 5.5 A on 110 V, well under the 9 to 15 A that Aerospace’s 1 hp and larger two-speed units draw.
How often do the filters need changing?
Aerospace America’s owner’s manual says to change the first-stage pre-filter daily when the unit runs around the clock, check the second-stage ring filter each time and change it weekly or as needed, and plan on replacing the HEPA filter about every 350 hours of use. The pressure gauge on the panel tells you when the HEPA is loading up.
What size filters does it take?
All three stages are 16 x 16 in: a 1/2 in pre-filter, a 1 in secondary filter and a 6 in deep HEPA. Ask our team for the matching Aerospace replacement filters.
Not sure the 1000V is the right size for your job?
Tell our team about the space, the containment and how long the job will run, and we will help you pick the right air scrubber and filters.
